Highlight Features

petroleum gas chromatograph

,

petroleum chromatograph analyzer

,

transformer gas chromatograph

Model NO.:
HZSP-II
Mass Scope Of Workpiece:
<900kg
Type:
Gas Chromatograph
Maxcapacity:
<1000KN
Accuracy Grade:
0.5
Load Way:
Electronic Load
Loading Method:
Static Load
Display:
Digital
Product Description
Product Overview

The HZSP-II is a laboratory-grade gas chromatograph engineered specifically for the analysis of petroleum products and transformer oil. It features a 7-inch color touch screen with a professional chromatography UI interface, providing intuitive, real-time display of inlet, column oven, and detector internal temperatures, individual detector values, and running time. A one-key cooling function simplifies operation, making the instrument both straightforward and convenient to use.

The instrument is widely applied across scientific research and education, petroleum, chemical, biochemistry, food safety, medicine and health, environmental monitoring, and judicial investigation. With high testing precision and excellent repeatability, it delivers dependable performance for demanding laboratory environments.

  • Resists high heat, humidity, and salt spray for tropical island use
  • Runs stably at -40°C, cold-proof and anti-condensation
  • IEC compliant, complete calibration certificates provided
  • Local support: spares, on-site training, and instrument calibration
HZSP-II Petroleum Product Transformer Oil Color Gas Chromatograph Meter For Laboratory
Product Features
  1. Optimized internal design. A new production process redesigns the gas source pathway and internal structure, resulting in a more reasonable component layout, reduced signal interference, improved detection accuracy, and excellent stability and durability.
  2. 7-inch color touch screen. The professional chromatography UI interface intuitively reflects inlet, column oven, and detector internal temperatures, individual detector values, and running time. A one-key cooling function and user-defined detection conditions enhance usability and convenience.
  3. Advanced column oven. Equipped with six independent temperature control systems and an automatic rear door opening system, supporting 21-order, 21-platform programmed temperature rise with fast heating and cooling. Temperature control accuracy reaches 0.05 °C, enabling a wide range of sample analysis.
  4. Modular, expandable architecture. The whole machine adopts a modular design and supports multi-processor parallel operation. It accommodates two injection port modules (capillary column and packed column) and five high-performance detector modules (FID, TCD, ECD, FPD, and NPD). Modules can be installed according to customer requirements, including customizable six-valve and ten-valve gas injectors, headspace injectors, thermal resolution injectors, cracking furnace injectors, and methane converters. It supports up to three groups of inlets and four types of detectors, making sample analysis convenient and future upgrades easy.
HZSP-II gas chromatograph modular interior showing injection ports and detector modules
Technical Parameters
Network Inverse Control System Internal CAN method with interface board design; can be converted to network output at will
Number of Signal Output Bits 24-bit
Communication Interface Network interface output (connected via Category 6 network cable)
Circuit Design ARM embedded design; supports wireless control, remote control, and mobile phone APP control
Temperature Control System Six independent temperature controls
Temperature Control Range Above room temperature to 450 °C; optional liquid nitrogen refrigeration: -80 °C to 450 °C
Column Temperature Control Accuracy ±0.02 °C
Programmed Temperature Rise Arbitrary order, 0.1 degree per order
Display Module Large-screen liquid crystal display
Display Accuracy 0.01 °C
Column Program Rise Rate 0–80 °C/min (adjustment increment 0.1 °C/min), up to 120 °C/min
Programmed Temperature Rise Repeatability ≤1%
Electronic Pressure Controller (EPC/EFC) Pressure range: 0–1000 kPa; full pressure control accuracy: 0.001 psi; maximum shunt ratio: 8000:1
TCD Detector Sensitivity S value ≥ 8000 mV·ml/mg (benzene), up to 12000 mV·ml/mg (benzene)
TCD Baseline Noise ≤10 uV
TCD Baseline Drift ≤50 uV/30 min
FID Detector Detection Limit ≤5.0 × 10-12 g/s (cetane)
FID Baseline Noise ≤2 × 10-14 A
FID Baseline Drift ≤1 × 10-13 A/30 min (after 2 hours of instrument stabilization)
ECD Detector Detection Limit ≤1.0 × 10-13 g/s (r-666)
ECD Baseline Noise ≤40 uV
ECD Baseline Drift ≤100 uV/30 min
FPD Detector Detection Limit ≤1.4 × 10-12 g/s (P); ≤5 × 10-11 g/s (S)
FPD Baseline Noise ≤20 uV
FPD Baseline Drift ≤50 uV/30 min
Expansion 6 external events can be added
Automation Engineering Optional additions: automatic ignition function, autosampler connection, four-way flow pressure display function, and reverse control workstation for reverse control
Product Dimensions
HZSP-II gas chromatograph dimensional drawing with measurements
Product Accessories
HZSP-II gas chromatograph included accessories and components
Company Profile
Similar Recommendations
Frequently Asked Questions
Q1: Is your company a sales or a manufacturer?

We are an integrated trade and manufacturing company with our own factory.

Q2: Can we customize our own brand or the built-in software of the machine?

Yes, we accept OEM/ODM/OBM and can customize the built-in software of the product according to the customer's special requirements.

Q3: What is the usual lead time? How long until we receive the order after placing it?

In normal circumstances, products in stock can be received within 5 to 7 days via the fastest international express. Other situations may vary depending on the quantity of products ordered, whether there are special customization requirements, and the delivery time chosen.

Q4: How can we ensure the product will not be damaged during transportation, considering its large size?

We have professional internal and external packaging to ensure the safety and stability of the products during transportation. For fragile or other special parts, we will include an extra set to ensure that the customer can use the product immediately upon receipt.

Q5: How do you handle after-sales service? What if there is a quality problem or the customer does not know how to operate the product?

For quality issues that are not caused by human error, we provide a one-year warranty from the time the product is delivered, along with lifetime technical support. Other after-sales issues will be addressed by our professional technical staff within 24 hours. The product comes with a user manual and an operation video.