HZJYY-JT Transformer Insulation Oil Tan Delta Tester Dielectric Loss Analyzer

Place of Origin: Wuhan, Hubei Province
Brand Name: HZRTZ POWER
Certification: GB/T19001-2016 idt ISO 9001:2015
Model Number: HZJYY-JT
Minimum Order Quantity: 1
Price: USD 1,000 - 10,000
Packaging Details: IPPC Fumigated wooden box (lSPM15)
Delivery Time: 5-7 working days
Payment Terms: T/T
Inquiry Now
Get a Quote
Specifications
Highlight Features

Insulation Oil Tan Delta Tester

,

Transformer tan delta test equipment

,

Dielectric Loss Analyzer

Model NO.:
HZJYY-JT
Display:
Digital
Portable:
Portable
Weight:
25kg
Power Voltage:
AC220V±10%
Power Frequency:
50Hz/60Hz±1%
Product Description
Product Overview

The HZJYY-JT Insulating Oil Dielectric Loss and Volume Resistivity Tester is designed and manufactured in accordance with GB/T5654-2007, "Measurement of Relative Permittivity, Dielectric Loss Factor and DC Resistivity of Liquid Insulating Materials." It is used to measure the dielectric loss factor and DC resistivity of insulating oils and other liquid insulating media.

The tester features an integrated structure that incorporates an oil cup for dielectric loss, a temperature controller, a temperature sensor, a dielectric loss test bridge, an AC test power source, a standard capacitor, a high resistance meter, a DC high voltage source, and other main components. Utilizing full digital technology, the instrument offers fully automated intelligent measurements and is equipped with a large 5.7-inch TFT full-color LCD touch display. The user-friendly interface and full English menu ensure that operators can use the instrument proficiently without specialized training. Test results can be automatically stored and printed.

  • Resists high heat, humidity, and salt spray for tropical island use
  • Runs stably at -40°C, cold-proof and anti-condensation
  • IEC compliant, with complete calibration certificates provided
  • Local support: spares, on-site training, and instrument calibration
HZJYY-JT Transformer Insulation Oil Tan Delta Tester Dielectric Loss Analyzer
Product Features
  1. Dielectric Loss Cup: Features an inter-electrode distance of 2mm, eliminating stray capacitance and leakage effects on dielectric loss measurements.
  2. Heating Method: Uses medium-frequency induction heating with PID temperature control for convenient control, maintaining the temperature within a preset error range.
  3. Standard Capacitor: The internal standard capacitor is an SF6-filled three-point electrode capacitor. Its dielectric loss and capacitance are unaffected by environmental temperature and humidity, ensuring precision over long-term use.
  4. Protection Features: Includes over-voltage, over-current, and high-voltage short circuit protection. The instrument quickly disconnects high voltage and issues warning messages in case of faults.
  5. Parameter Settings: Convenient settings for temperature (40–120°C), AC voltage (200–2200V), and DC voltage (0–500V).
  6. Display: Features a large TFT pure color LCD touch screen for clear display. The instrument automatically performs tests with simple settings and stores and prints test results.
  7. Empty Electrode Cup Calibration: Measures the capacitance and dielectric loss factor of the empty electrode cup to assess its cleaning and assembly condition.
  8. Core Platform: Based on the RAM9 platform, ensuring high testing precision and fast speed.
Detailed Photos
HZJYY-JT Transformer Insulation Oil Tan Delta Tester and Dielectric Loss Analyzer detailed view
Technical Parameters
Power VoltageAC220V ±10%
Power Frequency50Hz / 60Hz ±1%
Measurement Range — Capacitance5pF – 200pF
Measurement Range — Relative Permittivity1.000 – 30.000
Measurement Range — Dielectric Loss Factor0.00001 – 100
Measurement Range — DC Resistivity2.5 MΩm – 20 TΩm
Measurement Accuracy — Relative Permittivity±(1–10)% of reading
Measurement Accuracy — Dielectric Loss Factor±(5% of reading ± 0.0002)
Measurement Accuracy — DC Resistivity±10% of reading
Resolution — Capacitance0.01pF
Resolution — Relative Permittivity0.001
Resolution — Dielectric Loss Factor0.00001
Temperature Range40–120°C
Temperature Range Error±0.5°C
AC Test Voltage200–2200V continuously adjustable, frequency 50Hz
DC Test Voltage0–500V, continuously adjustable
Power Consumption500W
Dimensions460mm × 370mm × 330mm
Total Weight25Kg
Frequently Asked Questions

Q1: Is your company a sales company or a manufacturer?

We are an integrated trade and manufacturing company with our own factory.

Q2: If we need to customize our own brand or have special requirements for the built-in software of the machine, can it be customized?

Yes, we accept OEM/ODM/OBM and can customize the built-in software of the product according to the customer's special requirements.

Q3: What is the usual lead time? How long can we receive the order after placing it?

In normal circumstances, products in stock can be received within 5 to 7 days via the fastest international express. Other situations may vary depending on the quantity of products ordered, whether there are special customization requirements, and the delivery time chosen.

Q4: How can we ensure that the product will not be damaged during transportation, considering the large size of the product?

We have professional internal and external packaging to ensure the safety and stability of the products during transportation. For fragile or other special parts, we will include an extra set to ensure that the customer can use the product immediately upon receipt.

Q5: How do you handle after-sales service? What if there is a quality problem with the product or if the customer does not know how to operate it?

For quality issues that are not caused by human error, we provide a one-year warranty from the time the product is delivered, and lifetime technical support. Other after-sales issues will be addressed by our professional technical staff within 24 hours. The product comes with a user manual and an operation video.

Related Products
Send An Inquiry