Specifications
Highlight Features

pd free ac hipot test set

,

ac withstand voltage test equipment

,

power ac hipot test set

Current Test Error:
<1.0%+/-1d
Current Stability:
1.0%
Altitude:
1500 Meter Below
Quality Factor:
30~80
Delivery Lead Time:
10 Days
Environmental Humidity:
≤85% RH
Product Description
Product Overview

This motor-driven control console partial discharge (PD) free AC hipot test set is designed for power supply and distribution systems, power transformer manufacturers, industrial and mining enterprises, and scientific research institutions. It performs insulation strength tests under power frequency or DC high voltage on a wide range of high-voltage electrical equipment, electrical components, and insulating materials, making it indispensable key equipment for high-voltage testing. Its attractive, lightweight design simplifies and facilitates the entire test process.

  • Resists high heat, humidity, and salt spray for tropical island use
  • Runs stably at -40°C, cold-proof and anti-condensation
  • IEC compliant, with complete calibration certificates provided
  • Local support: spares, on-site training, and instrument calibration
HZDL Motor Driven Control Console Pd Free AC Hipot Test Set HV Withstand Voltage Test Equipment For Power Laboratory
Standard Equipment Configuration
1. Control Console
Parameter Item Specification
Power Input Single-phase AC 220V ±10%
Rated Capacity 5kVA
Input Current 22.7A
Output Voltage Single-phase 0 ~ 220V
Output Current 0 ~ 22.7A
Voltage Measurement Accuracy 0.5%
Current Measurement Accuracy 0.5%
2. Partial Discharge-Free Test Transformer
Parameter Item Specification
Rated Capacity 5kVA, single-phase
Rated Input Voltage 0.22kV
Rated Input Current 22.7A
Rated Output Voltage 50kV
Rated Output Current 0.1A (high-voltage winding)
Operating Frequency 50Hz
Cooling Method ONAN (Oil Natural Air Natural)
Continuous Operation Condition Long-term operation permitted under 80% rated load
Winding Temperature Rise ≤ 65K
Net Weight 100kg
3. Coupling Capacitor
Parameter Item Specification
Rated Voltage 50kV
Capacitance of High-Voltage Arm 300pF
Capacitance of Low-Voltage Arm 0.315μF
Operating Frequency 50Hz
Dielectric Loss Factor 0.0381%
4. Isolation Filter
Parameter Item Specification
Operating Frequency 50Hz
Rated Capacity 5kVA
Input Voltage 380V
Output Voltage 220V
Output Current 25A
Attenuation Performance 10kHz~100kHz ≥ 20 dB
Attenuation Performance 100kHz~30MHz ≥ 60 dB