HZJF-8000S Partial Discharge Detector Pd High Voltage Hipot Test Equipment

Place of Origin: Wuhan, Hubei Province
Brand Name: HZRTZ POWER
Certification: GB/T19001-2016 idt ISO 9001:2015
Model Number: HZJF-8000S
Minimum Order Quantity: 1
Price: USD 1,000 - 10,000
Packaging Details: IPPC Fumigated wooden box (lSPM15)
Delivery Time: 15-30 working days
Payment Terms: T/T
Inquiry Now
Get a Quote
Specifications
Highlight Features

high voltage partial discharge tester

,

high voltage partial discharge detector

Operating Temperature:
0~40℃
Host Size:
220mm*168mm*65mm
Active Section:
Voltage:0~10V; Output Current:0~10A
Network Interface:
WLAN Wireless Collection
Signal Line:
3m~5m
Storagetemperature:
-20°C To 60°C
Current:
5mA ~ 2A ± (Reading 3% + 0.05ma)
Service:
OEM Service Is Available
Product Description
Product Overview

The HZJF-8000S is widely applicable for partial discharge detection in power systems, including high voltage switchgear, ring main units, voltage/current transformers, transformers (including dry-type transformers), GIS, overhead lines, cables, and other equipment insulation status detection.

  • Resists high heat, humidity, and salt spray for tropical island use
  • Runs stably at -40°C, cold-proof and anti-condensation
  • IEC compliant, complete calibration certificates provided
  • Local support: spares, on-site training, and instrument calibration

HZJF-8000S Partial Discharge Detector Pd High Voltage Hipot Test Equipment

Product Features
  1. Equipped with various sensors for detecting partial discharge in almost all high voltage electrical equipment.
  2. Provides multiple discharge patterns such as time-domain waveform, PRPD, and PRPS, enabling analysis of different types of discharges.
  3. User-friendly interface for convenient data management of different devices.
  4. Built-in ultrasonic sensor and Transient Earth Voltage (TEV) sensor, with the capability to connect to specialized sensors for transformers, GIS, overhead lines, and cables.
  5. Noninvasive detection method that does not require power outage or additional high voltage source, making it more convenient than traditional pulse-type PD detectors.
  6. Testing bandwidth range of 30kHz to 2.0GHz, suitable for various frequency band detection principles.
Detailed Photos
HZJF-8000S partial discharge detector main unit with sensors and accessories
Technical Parameters
TEV Measurement AE Measurement
Measurement Range 0–60dBmV Measurement Range 0–60dBmV
Resolution 1dB Resolution 1dB
Accuracy ±1dB Accuracy ±1dB
Maximum per Cycle 1400 Frequency Range 20–200kHz
Measurement Bandwidth 3–100MHz

AA, AA1, AA2 Measurement UHF Measurement
Measurement Range 0–60dBmV Detection Frequency Band 300–2000MHz
Resolution 1dB Measurement Range 0–60dBmV
Accuracy ±1dB Sensitivity <1dBm
Sensor Center 40kHz Sensor Frequency Band 300–2000MHz
HFCT Measurement
Sensor Transportation 5mV/mA
Test Frequency 1–30MHz
Sensitivity ≤50pC
Hardware
Enclosure ABS
Display 4.0-inch with RGB LCD display, resolution 800×480
Sampling Accuracy 12 bit
Synchronization Method Internal synchronization
Connector USB port (also for charger input)
Earphone Minimum 8 Ω
SD Card Standard configuration 16G–64G
Built-in Battery 3.7V/10000mAh lithium battery
Working Time Approximately 12 hours
Charger DC 5V/3A
Operating Temperature -20–50ºC
Humidity 20–85% relative humidity
Dimension and Weight 210×100×35(mm)   0.4kg (main unit)
Product Dimension
HZJF-8000S partial discharge detector dimensional drawing with measurements
Company Profile
Company manufacturing facility exterior view Production workshop with assembly lines Quality control laboratory testing equipment Warehouse with organized inventory storage Engineering team collaborating on product development Calibration and testing of electrical instruments Packaging area with export-ready shipments
Similar Recommendation
Similar partial discharge detector model 1 Similar partial discharge detector model 2 Similar partial discharge detector model 3 Similar partial discharge detector model 4 Similar partial discharge detector model 5 Similar partial discharge detector model 6 Similar partial discharge detector model 7 Similar partial discharge detector model 8
FAQ

Q1: Is your company a sales or a manufacturer?

We are an integrated trade and manufacturing company with our own factory.

Q2: If we need to customize our own brand or if there are special requirements for the built-in software of the machine, can it be customized?

Yes, we accept OEM/ODM/OBM and can customize the built-in software of the product according to the customer's special requirements.

Q3: What is the usual lead time? How long can we receive the order after placing it?

In normal circumstances, products in stock can be received within 5 to 7 days via the fastest international express. Other situations may vary depending on the quantity of products ordered, whether there are special customization requirements, and the delivery time chosen.

Q4: How can we ensure that the product will not be damaged during transportation, considering the large size of the product?

We have professional internal and external packaging to ensure the safety and stability of the products during transportation. For fragile or other special parts, we will include an extra set to ensure that the customer can use the product immediately upon receipt.

Q5: How do you handle after-sales service? What if there is a quality problem with the product or if the customer does not know how to operate it?

For quality issues that are not caused by human error, we provide a one-year warranty from the time the product is delivered, and lifetime technical support. Other after-sales issues will be addressed by our professional technical staff within 24 hours. The product comes with a user manual and an operation video.

Related Products