HZWJF Power Frequency Withstand Test Equipment Hv Pd Partial Discharge Test System

Place of Origin: Wuhan, Hubei Province
Brand Name: HZRTZ POWER
Certification: GB/T19001-2016 idt ISO 9001:2015
Model Number: HZWJF
Minimum Order Quantity: 1
Price: USD 1,000 - 10,000
Packaging Details: IPPC Fumigated wooden box (lSPM15)
Delivery Time: 15-30 working days
Payment Terms: T/T
Inquiry Now
Get a Quote
Specifications
Highlight Features

power high voltage tester

,

power high voltage test equipment

,

partial high voltage tester

Model NO.:
HZWJF
Max Diameter Of Workpiece:
Unlimited
Mass Scope Of Workpiece:
<900kg
Type:
High Voltage Testing Machine
Maxcapacity:
<1000KN
Accuracy Grade:
1
Load Way:
Electronic Load
Loading Method:
Static Load
Display:
Digital
Control:
Computer Control
Weight:
0-100Kg
Power Source:
AC220V
Oil Cylinder Position:
Without
Usage:
Power Frequency Withstand , Partial Discharge Test
Function:
High Voltage Tester
Operation Place:
Indoor
Ground Resistance Value:
<0.5ω
Impedance Voltage:
10%
Output Voltage:
AC 0-1000kv
Partial Discharge:
Under Rated Voltage≤5PC
Output Voltage Waveform:
Power Frequency, Sine Wave
No-Load Loss:
0.2%-0.35%
Frequency:
50Hz
Phase:
Single Phase
Output Capacity:
50kVA
Output Current:
0.416A
Transport Package:
Wooden Box With Foam
Specification:
400X300X200 CM
Trademark:
HZRTZ POWER
Origin:
Wuhan, China
HS Code:
8504319000
Production Capacity:
120sets/Month
Product Description
Product Overview

The HZWJF series non-local discharge withstand voltage test device is primarily used for high-voltage circuit breakers, insulators, lightning arresters, switches, mutual inductors, cable accessories, high-voltage coils, and other specimens to carry out power frequency withstand voltage, partial discharge, and other scientific test research.

The complete set of equipment includes an intelligent insulation test comprehensive control system, digital correction pulse generator, input unit, frequency corona-free test transformer, non-local discharge coupling capacitor, non-local discharge protection resistor, electric regulator, and isolation filtering device.

The entire set of equipment is required to be used indoors with a good and dedicated grounding system. The grounding resistance value should be <0.5Ω — the smaller, the better.

HZWJF Power Frequency Withstand Test Equipment Hv Pd Partial Discharge Test System
Key Features
  • Resists high heat, humidity, and salt spray for tropical island use
  • Runs stably at -40℃, cold-proof and anti-condensation
  • IEC compliant, with complete calibration certificates provided
  • Local support: spares, on-site training, and instrument calibration
HZWJF power frequency withstand test equipment with partial discharge test system
Product Classification
No Local Discharge Control Section Partial Discharge Tester Non-Local Discharge Transformers
Manual Voltage Adjustment Analog Epoxy cartridge oil type
Electric Voltage Adjustment Digital Inflatable
Industrial control machine Control Touch Screen Optional
Digital Display Industrial control machine, can be interfaced with the State Grid EIP system Optional
Digital Display — —
PLC + Industrial computer, can be interfaced with the State Grid EIP system — —
Selection Guide

Voltage level refers to the test article, not the transformer.

Voltage Level (Test Article) Control Section Capacity Partial Discharge Tester Boosting Section Isolation Transformer Voltage Divider Protection Resistance
12kV switches, transformers, switch cabinets, etc. 5kVA and above Optional 50kVA and above 5kVA 50kV 50kV
24kV switches, transformers, switch cabinets, etc. 10kVA and above Optional 100kVA and above 10kVA 100kV 100kV
40.5kV switches, transformers, switch cabinets, etc. 20kVA and above Optional 120kVA and above 20kVA 120kV 120kV
Technical Parameters
I. HZWJF-50/120 Non-Local Discharge Withstand Voltage Test Device
HZWJF-50/120 non-local discharge withstand voltage test device control panel

The main interface of the touch screen can complete the same control functions as the upper computer. The panel can digitally display the current test voltage, test current, and other necessary information, and manually set up the boosting curve (set up the rated voltage, the local discharge test current, and other necessary parameters), and complete the local discharge, voltage withstand, and other tests with a single key.

The panel is equipped with an emergency stop button switch, which can be pressed in case of emergency and the system will automatically break the main circuit switch. The panel is equipped with a power button, which can be pressed to start the system with electricity.

The controller has an external control function, providing a start button, stop button, and test result status indicator that can be connected to the generator section. The controller has reserved interfaces for external red and green indicators, which can be used to install red and green indicators in the main loop body part.

Specifications
  1. Rated Output Capacity: 50kVA (Non-local Discharge Test)
  2. Rated Output Voltage: 120kV (Non-local Discharge Test)
  3. Rated Output Current: 0.416A (Non-local Discharge Test)
  4. Rated Input Voltage: 0.38kV
  5. Short-circuit Impedance: <6%
  6. Local discharge level of the complete set: <5pC at 100% rated voltage, ≤2pC at 80% rated voltage
  7. Running time: under 100% UH and 100% IH, it is allowed to run for 30 minutes from the ambient temperature; under 70% UH and IH, it is allowed to run continuously from the ambient temperature. The temperature rise of the transformer winding is ≤65K, and the temperature rise of the transformer oil is ≤55K.
  8. Waveform distortion rate of the set: regulator input voltage waveform distortion rate <3%; complete sets of equipment output voltage waveform distortion rate ≤3%
II. YDTW-50kVA/120kVA Non-Local Discharge Test Transformer
  1. Structure Type: insulated shell oil-immersed natural cooling, single unit composition
  2. Phases Number: single-phase
  3. Frequency: 50Hz
  4. Rated Input Voltage: 0.38kV
  5. Rated Input Current: 131.5A
  6. Rated Output Voltage: 150kV
  7. Rated Output Current: 0.416A
  8. Rated Output Capacity: 50kVA
  9. Measured winding voltage ratio: 1000:1
  10. Waveform distortion rate: ≤3%
  11. Dielectric loss factor: tanδ <0.3% (90ºC)
  12. Partial discharge: ≤5pC under 100% rated voltage, ≤2pC under 80% rated voltage
  13. Insulation level: 110% rated self-induced withstand voltage for 1 minute
  14. Overcurrent Capacity: effective measures should be taken (additional protective resistors, etc.), so that the test transformer in the test product insulation breakdown phenomenon should not cause damage to the test transformer; in 110% rated current duration of 1min working conditions, overcurrent on the test transformer should not cause thermal damage and deformation of the windings.
  15. Over-Voltage capability: in 110% UH (220KV) time 1min under over-voltage, should not cause any insulation damage to the test transformer, when the waveform distortion rate ≤5%.
  16. Running time: in 100% UH, IH from the ambient temperature is allowed to run 60 minutes; in 70% UH, IH from the ambient temperature is allowed to run continuously. Transformer winding temperature rise ≤65K, oil surface temperature rise ≤55K.
  17. Noise level: ≤65db
  18. Insulating oil performance: oil withstand voltage ≥60kV; water content ≤10ppm
  19. Dielectric loss (90ºC) ≤0.4%
III. TYDZ-50/0.38/0~0.42 Column Regulators
  1. Phase Number: Single-phase
  2. Frequency: 50Hz
  3. Rated Capacity: 50kVA
  4. Rated Input Voltage: 0.38kV
  5. Rated Input Current: 131.5A
  6. Rated Output Voltage: 0~0.42kV
  7. Rated Output Current: 119A
  8. Waveform distortion rate: ≤3%
  9. Starting voltage: ≤2%
  10. Short-circuit impedance: ≤8% (within 50%~100% voltage regulation)
  11. Structure form: column, dry type
  12. Short-circuit capacity: transient capacity state of the test transformer output through the protective resistor on the test piece discharge, short-circuit current up to 2 times the output, discharge duration of 8 weeks should not be within the regulator winding caused by any thermal damage and mechanical deformation.
  13. Voltage regulating method: electric voltage regulating, using DC motor drive
  14. Regulator with upper and lower limit devices
  15. Running time: Same as transformer
Company Profile
Similar Recommendation
Frequently Asked Questions
Q1: Is your company a sales or a manufacturer?

We are an integrated trade and manufacturing company with our own factory.

Q2: If we need to customize our own brand or if there are special requirements for the built-in software of the machine, can it be customized?

Yes, we accept OEM/ODM/OBM and can customize the built-in software of the product according to the customer's special requirements.

Q3: What is the usual lead time? How long can we receive the order after placing it?

In normal circumstances, products in stock can be received within 5 to 7 days via the fastest international express. Other situations may vary depending on the quantity of products ordered, whether there are special customization requirements, and the delivery time chosen.

Q4: How can we ensure that the product will not be damaged during transportation, considering the large size of the product?

We have professional internal and external packaging to ensure the safety and stability of the products during transportation. For fragile or other special parts, we will include an extra set to ensure that the customer can use the product immediately upon receipt.

Q5: How do you handle after-sales service? What if there is a quality problem with the product or if the customer does not know how to operate it?

For quality issues that are not caused by human error, we provide a one-year warranty from the time the product is delivered, and lifetime technical support. Other after-sales issues will be addressed by our professional technical staff within 24 hours. The product comes with a user manual and an operation video.

Related Products
Send An Inquiry